Free template

Walk-in temperature
log.

A month of daily product-temperature checks on one sheet. Print it, clip it to the walk-in door, and the HACCP log fills itself in one reading at a time. Instructions included, because the reading is only useful if it is taken the way an inspector would take it.

How to take the reading

Measure product temperature, not air. Keep a probe thermometer in a container of water on a middle shelf and read that. The door display reads air, which swings with every defrost cycle and every delivery; the water reads like the food does, and it is the number a health inspector trusts.

The target range is 35–38°F. That keeps every shelf under the 41°F FDA cold-holding line with margin for door openings and defrost. Log twice a day, once in the morning before deliveries and once during the afternoon.

When a reading is over 41°F: check the door and gaskets, note the corrective action in the log, and re-check within the hour. Chilled food above 41°F for more than a limited window, commonly around four hours, has to be discarded. The full background is in how cold a walk-in should be.

Watch for drift, not just bad readings. A log that creeps from 36 to 38 over three weeks is telling you something even though every reading passed. Slower recovery and a rising average are how faults look before they are failures; what one costs is in the walk-in failure cost calculator.

Day AM °F PM °F Corrective action (if over 41°F) Initials Verified
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
See it on your units

Which units give you the most trouble?

Pick a time that suits. We'll walk through what it would catch on your units, what the alerts look like, and what a rollout takes.

Got a question?

Not ready for a call? Just ask.

Leave your question and an email. We read everything and reply directly, no sequence, no cadence.

The failure library, as it grows.

Guides on catching HVAC and refrigeration failures early. No schedule, no spam.